23
NOTA
1)ROOM TEMPERATURE CONTROL
Cooling
•Room temperature control is obtained by cycling the compressor ON and OFF under control of the room
temperature sensor in the remote control unit.
F
FUNCTION
•The control circuit will not attempt to turn the compressor ON until the compressor has been OFF for at
least 3 minutes.
To protect the compressor from stalling out when trying to start against the high side refrigerant pressure,
the control circuit has a built-in automatic time delay to allow the internal pressure to equalize.
•As a protective measure, the control circuit switches the compressor OFF after 5 minutes or more of
compressor operation.
•Thermo ON: When the room temperature is above T + 1°C (T°C is set temperature).
Compressor ➔ ON.
•Thermo OFF:When the room temperature in equal to or below set temperature T°C.
Compressor ➔ OFF.
MORE THAN
5 MINUTES
THERMO OFF
MORE THAN
3 MINUTES
THERMO
ON
THERMO
OFF
MORE THAN
5 MINUTES
3 MINUTES 5 MINUTES
THERMO
ON THERMO
OFF
WITHIN
3 MINUTES
WITHIN
5 MINUTES
ONOFFONOFFON
ROOM TEMPERATURE
OFFON ONOFFON
SET SPEED (MANUAL)
SET T + 0,5 ϒC
TEMPERATURE T ϒC
COMPRESSOR
OUTDOOR
FAN
INDOOR
FAN